Technical Bulletins

Technical Information / Technical Bulletins

Technical Bulletin 15

Simple Saver System™ Acoustical properties

The following are test results of Simple Saver System samples tested in accordance with ASTM C423 to determine acoustical absorption.

Acoustical Test Results per ASTM C423

Sample #1: Tested Manville Acoustical Labs, 7/12/89 in Denver, CO. Standard weight Simple Saver liner fabric (woven coated polyethylene with flame retardance), 5- to 6-mils thick on 6" or more of 0.6 lbs/cubic ft. density fiberglass; 0.26 psf weight liner fabric.

Sound Absorption Coefficients

Frequency (Hz) Band:
125 250 500 1000 2000 4000 NRC
1.22 1.17 0.78 0.68 0.39 0.22 0.75


Sample #2: Tested by Geiger & Hamme, Inc. Acoustical, 8/21/91, Ann Arbor, MI. Lightweight Simple Saver liner fabric (woven coated polyethylene), 3- to 5-mils thick on 6" or more of 0.6 lbs/cubic ft. density unfaced fiberglass; 0.22 psf weight liner fabric.

Sound Absorption Coefficients

Frequency (Hz) Band:
125 250 500 1000 2000 4000 NRC
0.39 0.87 1.03 0.81 0.62 0.41 0.85

 

Please call Thermal Design at 800-255-0776 for more information, designs or custom testing of assemblies.