Technical Bulletins

Technical Information / Technical Bulletins

Technical Bulletin 20

Syseal™ Sticky Tape Usage Guidelines

 

When installing the Simple Saver System™, refer to the following guidelines regarding Syseal™ Sticky Tape:

  • Use Syseal™ Sticky Tape to seal fabric to clean, dry metal structural surfaces.
  • Apply with firm pressure before removing facing, and after liner fabric is adhered.
  • Recommended application temperature to achieve best results is 65˚ F. Proper bonding may not occur unless the adhesive and surface material are both at the recommended temperature.
  • Rolls should be stored on end and in a cool, dry place below 76˚ F.
  • Simple Saver High Tack Sealant™ and/or Simple Saver Pressure Sensitive Sealant™ (spray) is recommended in all other applications unless otherwise noted.